User Tools

Site Tools


wiki:sns:snspro:failure_criteria

Failure Criteria

Scan&Solve Pro supports the following failure criteria:

  • Von Mises -used for ductile materials.
  • Maximum Shear Stress -used for ductile materials, it is also known as the Tresca or Guest criterion and is slightly more conservative than the von Mises criterion.
  • Rankine -used for brittle materials, it is also known as maximum normal stress criterion.
  • Coulomb Mohr -used for brittle materials, more conservative than Rankine criterion.
  • Modified Mohr -used for brittle materials, more conservative than Coulomb Mohr criterion.

Scan&Solve Pro computes the Danger Level in the [View] tab based on the Yield Strength, Tensile Strength, and Compressive Strength specified in the material database. The von Mises and maximum shear stress failure criteria are only applicable to ductile materials- materials that flex, stretch, or compress significantly before failure. The Rankine, Coulomb-Mohr, and Modified Mohr failure criteria are only applicable to brittle materials such as glass, ceramics, and concrete- materials that fail without significant deformation.

Different failure criteria may be selected when editing material properties. When editing, the von Mises and Maximum Shear Stress criteria require a positive yield strength to be specified. The Rankine, Coulomb-Mohr, and Modified Mohr criteria require positive tensile strength and compressive strength entries.

wiki/sns/snspro/failure_criteria.txt ยท Last modified: 2017/07/14 12:08 by claire